AUTOPOL V PLUS Automatic Polarimeter
  • Information
  • Specifications

AUTOPOL V PLUS Polarimeter

The AUTOPOL V® has the validation tools and features to satisfy today’s global pharmaceutical companies, including: instrument level 21CFR Part 11 compliance, NIST traceable calibration standards and a global list of installations. Rudolph Research has thousands of satisfied customers who praise the Autopol® V’s quality, accuracy and reproducibility.

AUTOPOL V Standard Features and Accessories

  • TempTrol™ — Electronic cooling & heating from 15°-35°C
  • Six Standard Wavelengths: 365nm, 405nm, 436nm, 546nm, 589nm and 633nm
  • 21CFR11 Compliance: Electronic Signature and secure local electronic data storage
  • Domestic 3-year warranty and 20-year support guarantee
  • International warranty varies by country
  • Standard Accessories: TempTrol™ NIST Traceable Quartz Standard (single rotation), TempTrol™ 100mm Polarimeter Cell, TempTrol™ Temperature Validation Cell, Built-In Sample Measurement Probe

The AUTOPOL V Plus Advantage

  • 6m HCl acid resistance: Silco Steel coating on the chamber temperature transfer surface and a Hastelloy measurement cell with NIST certificate certifying optical path length.
  • To meet the FDA’s latest position on measurement bracketing, the Autopol® V Plus comes with a NIST traceable quartz plate with three rotations: +0.998° Arc, +10.998° Arc, -10.000° Arc. Each rotation has a NIST certificate.
  • The AUTOPOL V PLUS comes with a NIST traceable quartz plate with 3 rotations
  • Windows based navigation architecture is so intuitive that most operators will never read the manual. But should you wish to reference the manual, it is stored right on the Autopol® V Plus’ internal memory.
  • Available with automated sampling.
    Easy Clean Sampling System
  • Three USB ports allow quick and easy connection to a mouse, keyboard, printer, bar code scanner, or memory stick. One USB port is located on the front of the unit (shown above) and two USB ports are located on the back of the unit (shown below).
    USB and Ethernet ports on the back of the Autopol V Plus
  • Ethernet Port for Network Cable Connection
  • Internet access allowing connection to Rudolph’s service department for remote testing and diagnostics
  • Connect to any Windows® based printer via USB or direct to the server via Windows® Print Library
  • Save measurement data direct to your Network/Server

Patented TempTrol™ Technology Eliminates the Need for a Water Bath. Here is How the TempTrol™ System Works:

TempTrol active surface with Silco Steel coating

TempTrol heating and cooling transfer surface

TempTrol Hastelloy passive surface

TempTrol cell with mating heating & cooling transfer surface manufactured with acid resistance materials: Hastelloy™ and Peek™.

Temperature is selected via touch screen. Temperature selection of 20°C shown left.

Place the TempTrol cell in your TempTrol equipped Autopol® sample chamber to measure within ±0.2°C of the USP, EP, JP, or BP specified temperature (normally 20°C or 25°C ±0.5°C). For improved temperature performance or when working with acids (HCl) use the measurement port in the body of the cell. This also allows the inlet and outlet ports to be capped to avoid evaporation, fumes and spillage.

Rudolph provides a temperature validation cell with every TempTrol system. The temperature validation cell along with optional NIST traceable thermometer is designed to validate the temperature control performance of the polarimeter and cell to ±0.2°C.

Intuitive Windows® Based Interface

  • 2 gigabytes of internal memory allow almost unlimited capacity for saving measurement data. The AUTOPOL V PLUS is network ready and data may also be saved directly to your server or to any directory desired.
  • Internet access is possible directly from the AUTOPOL V PLUS's touch screen. This feature allows real time contact with Rudolph Research Analytical's Service and Technical Support Team who can access your instrument remotely to assist in Window navigation, method setup and troubleshooting.
  • Windows based navigation architecture is so intuitive that most operators will never read the manual. But should you wish to reference the manual, it is stored right on the AUTOPOL V PLUS's internal memory.
  • Three USB ports allow quick and easy connection to a mouse, keyboard, printer, bar code scanner, or memory stick. One USB port is located on the front of the unit and two USB ports are located on the back of the unit.

 

Flexible Method Management

Install your own measurement methods for immediate selection of the correct method to match your most common tests. Setting up your own custom methods is as simple as filling out a few screens like the one shown to the right.

Method Select Screen

 

Method Setup Screen

 

Full 21CFR Part 11 Instrument Level Compliance

The AUTOPOL V PLUS's 21CFR Part 11 software module is easily enabled through the user friendly touch screen. This module gives you full compliance with:

  • Electronic signature
  • Access levels
  • Internal write protected storage
  • Unique passwords
  • Write protected documents sent directly to server
  • Audit trail
21CFR Part 11 Compliance Screens

 

Acid Resistance

The AUTOPOL V PLUS comes standard with Rudolph's Hastelloy™ upgrade option. This option includes a Hastelloy cell and Silco Steel™ cell chamber for increased resistance to acids like 6 Molar HCl.

 

Rudolph Research Analytical — still protecting your investment after 30 years

Today our Service Technicians have access to state of the art diagnostic tools and have a depth of knowledge that often lets them solve problems right over the phone. Our customers really appreciate the same day phone call by a real technical service person who wants to solve their problem. Our customers know that they can expect this support for many years to come as Rudolph is still repairing instruments which were built in the 70's.